Remote PTO will provide your application with the desired speed control. Setup of the desired engine speeds is necessary for proper operation. The control limits for Remote PTO are carried over from the setup of PTO's features and parameters.

Remote PTO
Choose this feature if the benefits and convenience of Remote PTO's accurate speed control are desired.

Remote PTO Number of Speed Settings
Specify the number of speed settings desired. This parameter defines the number of speed settings that can be used during the operation of Remote PTO. The range is between 1 and 5.

Remote PTO Speed Setting 1
Specify the engine speed desired for Remote PTO Speed Setting 1. This is the engine speed that will be used when the operator requests speed 1 with the Remote PTO switch. The range is between PTO Minimum and Maximum Engine Speeds.

Remote PTO Speed Settings 2 thru 5
Specify the engine speed desired for Remote PTO Speed Settings 2-5. These are the engine speeds that will be used when the operator requests speed 2-5 with the Remote PTO switch. The range is between PTO Minimum and Maximum Engine Speeds.

Feature/Parameter

Range

Default

Feature Option

Enable/Disable

Disable

Number of Speed Settings - Parameter

1 - 5

1

Speed Setting 1 - Parameter

PTO Min - PTO Max rpm

1200 rpm

Speed Settings 2 thru 5 - Parameter

PTO Min - PTO Max rpm

800-1100 rpm

PTO Transmission Interlock - Feature Option

Enable/Disable

Disable